If the Smart Field is using a Static Selection the results won’t automatically refresh when the Smart Field is processed.

To resolve this:
  1. Go to Administration > Smart Fields.
  2. Highlight the Smart Field and select Edit.
  3. On the Parameters tab take note of the selection that the smart field uses.
  4. Go to Query and search for the query in question.
  5. Open the Query and select Edit Definition.
  6. Select File > Properties.
  7. On the Options tab select to create a Dynamic Selection instead of a Static Selection.
  8. Click Ok.
  9. Go to Administration > Smart Fields.
  10. Highlight the Smart Field and select Process Smart field.
  11. Rerun the Query.