1.  Make a backup (BB710507) of the division:
2.  Rebuild the ##pyk file:
 
  Select File -> Open FundWare.
  Verify that 00 - System Administration appears in the drop down box, click OK.
  Select System Administration -> System Utilities.
  Enter the following in the Execute Program portion of the screen:
       Program Name                   AFW800
       Switches                           <blank>
       Parameters                        AFW807
       Business Date                    Use today's date
       Division                  Select the appropriate division.
       Click Run.
    Hit enter at the blue screen.
    The DOS prompt appears.
    Click anywhere on the black screen to put the cursor next to the data prompt.
    At the DOS prompt, type: del tp*.* (press enter)
   Type: dir   *.sq (press enter).  It should say "File not found."
(For the following steps, replace ## with your 2 digit division number.)
   Type:  rename    ##pyk*.*    99pyk*.* (press enter).  
   Type: rebuild  99pyk,##pyk   /d  (press enter).
You should receive the message "rebuilding of corrupt data completed - records read =  ##
Corrupt records recovered =  ##"   when it completes.

3.  In the 00 System Admin:
Select System Administration -> System Utilities.
  Enter the following in the Execute Program portion of the screen:
       Program Name                   PYL953
       Switches                            1
       Parameters                        (blank)
       Business Date                    Use today's date
       Division                  Select the appropriate division.
       Click Run.
Answer Yes to all the prompts.  This will create a pyl953 report in your print manager.  If it has errors, run the above program with a switch of 2, to correct the errors.  If the report is blank, you do not need to run the program again.

4.  In the 00 System Admin:
Select System Administration -> System Utilities.
Enter the following in the Execute Program portion of the screen:
       Program Name                   AFW800
       Switches                           <blank>
       Parameters                        AFW807
       Business Date                    Use today's date
       Division                  Select the appropriate division.
       Click Run.
    Hit enter at the blue screen.
    The DOS prompt appears.
    Click anywhere on the black screen to put the cursor next to the data prompt.
    At the DOS prompt, type: rename  ##pyj*.*   xxpyj*.* (Replace ## with your 2 digit division number.) (press enter)
Then go back to program name and run:
      Program Name                   PYL900
       Switches                           <blank>
       Parameters                        <blank>
       Business Date                    Use today's date
       Division                  Select the appropriate division.
       Click Run.  Just answer Yes to all prompts